Probe errors analysis and correction are the key technique in time-domain near field measurement.We deduced the transform formulas of probe receiving character error function between different coordinate systems;used `time-window' to get rid of the multi-reflection wave
and presented the selection principle of `time-window'.Numerical results illustrated the efficiency of the new ways.