A Simple Implementation of Hysteretic-Current-Loop-Control High Power Factor Boost Type Convert
Based on the analysis of the switch time in the traditional Hysteretic-Current-Loop-Control Boost Type Power-Factor-Correction(PFC)circuit
this paper proposes a simple control mode.To achieve PFC
this mode divides the logical control into two parts
then it determines the prescribed maximum inductor current and the minimum inductor current respectively by constant turn-on time technology and the average inductor current signal.In experimental circuit
a RC low-filter replaces the multiplier and the input voltage sensor of traditional mode and the measurement gets near unit power factor.