An equivalent time-domain linear network model is obtained for multiconductor transmission lines with nonzero initial voltage and current distributions by combining Fourier and Laplace transforms. The transmission lines may be lossy non-uniform ones. The model can be embedded in a circuit simulator such as SPICE
so nonlinear terminal loads can be treated. One example of transient analysis using the model is given.