[1]王虎符,伍远生,杨叔孔.模拟电路的等输入/等输出k故障屏蔽方法[J].电子学报,1988,{4}(03):84-89.
Wang Hu-fu, Wu Yuan-sheng and Yang Shu-kong. Equal Input/Equal Output k Fault Screen Method in Analog Circuits[J]. Acta Electronica Sinica, 1988, (3): 84-89.
本文提出模拟电路故障定位的一种新方法——故障屏蔽方法。通过求解一组低阶齐次线性方程而得到一组最优激励
检查标称网络在最优激励下的被屏蔽支路集
即可对故障定位。文中还讨论了在考虑元件容差时进行故障定位的措施。
Fault screen method
a new method for fault location in analog circuits
is p-resented. By solving a set of low order homogeneous linear equations to obtain a optimum stimulus
and by checking the screened branches in the nominal network excited by this optimum stimulus
the faulty branches can be located. Taking the tolerances of the nonfaulty elements into consideration
some techniques for fault location are discussed.