[1]曹康白,窦文斌,薛良金.小型氢脉塞金属加载谐振腔的研究[J].电子学报,1985(03):42-50.
Tsao Kang-bai, Dou Wen-bin and Xue Liang-jin. Study of Compact Resonance Cavity for Hydrogen Maser[J]. Acta Electronica Sinica, 1985, (3): 42-50.
本文对氢脉塞小型谐振腔进行了理论和实验研究。用变分法给出金属加载圆波导的载止波数的上、下限
以及加载圆柱形谐振腔的f
0
、Q
0
和η’。计算结果与实验一致性较好
可供腔体设计参考。还得出了与前人不同的一些结论。
A theoretical and experimental study is conducted for the compact resonance cavity for hydrogen maser. The mothed of variation is used to calculate the upper and lower limits of cut-off wave numbers in circular wave guides loaded with metallic sheets
yielding f0
Q0 and η’ of loaded circular cavities. The results of calculation are found well consistent with those of experiment
and hence are useful in cavity design. Some of the conclusions obtained are different from those of other authors.