本文用严格的数学方法分析了积分电容的介质吸收效应引起的双积分模数转换的误差。证明了当连续进行双积分模数转换时
只要对某一被测电压测试足够多次数后
电容器的介质吸收将不会引起测量误差。文中导出了误差的计算公式
并由此决定了误差变化的时间常数。
This paper analyses the dual-ramp A to D converter error due to dielectric absorption of the integrator capacitor with a rigorous mathematical method. It is proved that if the dual-ramp A to D converter runs continuously and if same voltage have been measured for a sufficiently long time the dielectric absorption of the integrator capacitor will not cause any error. When measured voltage changes abruptly the dielectric absorption of capacitor will cause error for first a few measurements. The formula for calculating error and its time constant is obtained.