本文利用谐振腔反射现象测量圆波导衰减的概念
对矩形波导短样品的衰减进行了测试。本法要求的设备简单、操作方便。曾对0.76米
0.60米
0.22米和0.09米等不同长度、不同质量、不同加工方式的矩形波导样品进行多次测量。结果表明:测量0.1分贝的样品衰减时
随机误差约1.5%
总误差不大于10%。本方法可以分辨不同质量的波导样品。 文中提出了选定线路元件参数以保证所需测量准确度的建议
实验证明这样的选择是恰当的。此外
还利用标准片移式衰减器作了总体验证。
The development of techniques for measuring attenuation of a piece of rectangular waveguide is discussed. Measurement is carried out on the basis of the reflection of resonator formed by waveguide.Measurements are performed on waveguide of different lengths
(0.76m
0.60m
0.22 m and 0.09 m) different materials
and different manufacturing methods. Experimental data show that when attenuation of waveguide is on the order of 0.1 db
the random error is about 1.5%
and the total error is more than 10%. With such method it is easy to distinguish waveguide of different materials.Method of selecting parameter of waveguide element for given accuracy is considered. Accuracy is verified by a standard vane type attenuator.