YE Peng, ZENG Hao, TIAN Shu-lin, et al. Research on the Real-time Calibration Technology for High-Speed Parallel Sampling[J]. Acta Electronica Sinica, 2013, 41(1): 166-170.
DOI:
YE Peng, ZENG Hao, TIAN Shu-lin, et al. Research on the Real-time Calibration Technology for High-Speed Parallel Sampling[J]. Acta Electronica Sinica, 2013, 41(1): 166-170. DOI: 10.3969/j.issn.0372-2112.2013.01.029.
Research on the Real-time Calibration Technology for High-Speed Parallel Sampling
Errors of time non-uniform and amplitude non-uniform in parallel sampling seriously influence the performance of the system.This paper established a mathematical model of parallel alternating acquisition system
and realized a normalized correction algorithm for non-uniform amplitude error.This method not only introduced programmable reference voltage source
but also corrected the offset and gain error at the same time by the method of look-up table.Finally
the calibration system estimate the time of non-uniformity parameters
which can be corrected by controlling the high precision programmable clock delay network.The correction method proposed in the thesis
after testing and verifying
is proved to increase the correction performance with high real-time performance
while reducing the design difficulty of hardware and system costs.