Abstract:The purpose of the study was to reduce the noise and artifact in the phase-contrast computed tomography image of a tristructural-isotropic coated fuel particle.Three algorithms were proposed to reduce the noise and artifacts caused by the stochastic noise,non-linear drifting,and non-uniform sensitivity of the imaging detector,respectively.Subjective and quantitative evaluations were conducted before and after applying the algorithms.The results demonstrated that the proposed algorithms effectively reduced the three types of noise and artifacts,leaving the boundaries between different structures intact.
彭亚辉, 曹旭阳, 陈后金, 李艳凤, 李居朋, 王贤刚. 三结构各向同性包覆燃料颗粒相衬CT图像的噪声和伪像抑制方法初探[J]. 电子学报, 2019, 47(2): 448-453.
PENG Ya-hui, CAO Xu-yang, CHEN Hou-jin, LI Yan-feng, LI Ju-peng, WANG Xian-gang. Preliminary Study on Noise and Artifact Reduction in Phase-Contrast CT Image of Tristructural-Isotropic Coated Fuel Particle. Acta Electronica Sinica, 2019, 47(2): 448-453.
[1] 张永栋,林俊,张海青,等.包覆燃料颗粒尺寸及其标准偏差对失效概率的影响[J].核技术,2016,39(12):69-74.
[2] Yang M,Zhang J,Song S J,et al.Imaging and measuring methods for coating layer thickness of TRISO-coated fuel particles with high accuracy[J].Ndt & E International,2013,55(3):82-89.
[3] Kim W K,Lee Y W,Cho M S,et al.Nondestructive measurement of the coating thickness for simulated TRISO-coated fuel particles by using phase contrast X-ray radiography[J].Nuclear Engineering & Design,2008,238(12):3285-3291.
[4] Yang M,Zhang J,Meng F,et al.Denoising method of X-ray phase contrast DR image for TRISO-coated fuel particles[J].PARTICUOLOGY,2013,11(6):695-702.
[5] Yu L,Leng S,Mccollough C H.Dual-energy CT-based monochromatic imaging[J].Ajr American Journal of Roentgenology,2012,199(5 Suppl):S9-S15.
[6] 王贤刚,张朝宗,郭志平.CT图像线状伪像产生的原因和校正方法[J].核电子学与探测技术,2009,29(1):101-104.
[7] 李俊江,胡少兴,李保磊,等.CT图像环状伪影校正方法[J].北京航空航天大学学报,2007,33(11):1378-1382.
[8] Chen R C,Dreossi D,Mancini L,et al.PITRE:Software for phase-sensitive X-ray image processing and tomography reconstruction[J].Journal of Synchrotron Radiation,2012,19(5):836-845.
[9] Katsevich A.Theoretically exact filtered backprojection-type inversion algorithm for spiral CT[J].Siam Journal on Applied Mathematics,2002,62(6):2012-2026.
[10] Soille P.Morphological Image Analysis:Principles and Applications[M].Springer-Verlag New York,Inc.2003.
[11] Buades A,Coll B,Morel J M.A non-local algorithm for image denoising[A].Computer Vision and Pattern Recognition,2005.CVPR 2005.IEEE Computer Society Conference on[C].IEEE,2005.60-65 vol.2.
[12] Kim Y,Baek J,Hwang D.Ring artifact correction using detector line-ratios in computed tomography[J].Optics Express,2014,22(11):13380-92.
[13] Eldib M E,Hegazy M,Mun Y J,et al.A ring artifact correction method:validation by micro-CT imaging with flat-panel detectors and a 2D photon-counting detector[J].Sensors,2017,17(2):269.