[1] 宋佳凝,徐国栋,李鹏飞.基于相位差测量的脉冲星时间相对导航方法[J].宇航学报,2016,37(11):1304-1311. SONG JN,XU GD,LI PF.Pulsar based time relative navigation method using phase difference measurement[J].Journal of Astronautics,2016,37(11):1304-1311.(in Chinese)
[2] VU A?U1 IJAK,NADA M,SARANOVAC L.A simple algorithm for the estimation of phase difference between two sinusoidal voltages[J].IEEE Transactions on Instrumentation and Measurement,2010,59(12):3152-3158.
[3] 马晓红,李瑞,殷福亮.基于信号相位差和后置滤波的语音增强方法[J].电子学报,2009,37(9):1977-1981. MA XH,LI R,YIN FL.A speech enhancement method based on phrase-error and post-filtering[J].Acta Electronica Sinica,2009,37(9):1977-1981.(in Chinese)
[4] HOU QL,XU KJ,FANG M,et al.Development of Coriolis mass flowmeter with digital drive and signal processing technology[J].Isa Transactions,2013,52(5):692-700.
[5] ASSOUS S,LINNETT L.High resolution time delay estimation using sliding discrete Fourier transform[J].Digital Signal Processing,2012,22(5):820-827.
[6] TU YQ,ZHANG HT.Method for cmf signal processing based on the recursive DTFT algorithm with negative frequency contribution[J].IEEE Transactions on Instrumentation & Measurement,2008,57(11):2647-2654.
[7] 沈廷鳌,涂亚庆,李明,等.基于一类新窗的滑动DTFT相位差测量算法及分析[J].中南大学学报(自然科学版),2015,46(4):1302-1309. SHEN TA,TU YQ,LI M,et al.New sliding DTFT algorithm for phase difference measurement based on a new kind of windows and its analysis[J].Journal of Central South University (Science and Technology),2015,46(4):1302-1309.(in Chinese)
[8] SHEN TA,TU YQ,LI M,et al.A new phase difference measurement algorithm for extreme frequency signals based on discrete time Fourier transform with negative frequency contribution.[J].Review of Scientific Instruments,2015,86(1):0151041-0151049.
[9] SHASWARY E,TAVAKKOLI J,XU Y.A new algorithm for time-delay estimation in ultrasonic echo signals[J].Ultrasonics Ferroelectrics & Frequency Control IEEE Transactions on,2015,62(1):236-241.
[10] 沈廷鳌,涂亚庆,刘翔宇,等.基于相关原理的非整周期信号相位差测量算法[J].仪器仪表学报,2014,35(9):2153-2160. SHEN TA,TU YQ,LIU XY,et al.Research on phase difference measurement for non-integer period sampling signal based on correlation theory[J].Chinese Journal of Scientific Instrument,2014,35(9):2153-2160.(in Chinese)
[11] 沈廷鳌,涂亚庆,李明,等.数据延拓式相关的相位差测量方法及验证[J].仪器仪表学报,2014,35(6):1331-1337. SHEN TA,TU YQ,LI M,et al.Research and validation on improved correlation method for phase difference measurement based on data extension[J].Chinese Journal of Scientific Instrument,2014,35(6):1331-1337.(in Chinese)
[12] TU YQ,SHEN YL,ZHANG HT,et al.Phase and frequency matching-based signal processing method for Coriolis mass flowmeters[J].Measurement Science Review,2016,16(2):62-67.
[13] SVETE A,KUTIN J,BOBOVNIK G,et al.Theoretical and experimental investigations of flow pulsation effects in Coriolis mass flowmeters[J].Journal of Sound & Vibration,2015,352(9):30-45.
[14] 刘维来,赵璐,王克逸,等.基于希尔伯特变换的科氏流量计信号处理[J].计量学报,2013,34(5):446-451. LIU WL,ZHAO L,WANG KY,et al.Signal processing for Coriolis mass flowmeter based on Hilbert transform[J].Acta Metrologica Sinica,2013,34(5):446-451.(in Chinese)
[15] TU YQ,YANG HY,ZHANG HT,et al.CMF signal processing method based on feedback corrected ANF and Hilbert transformation[J].Measurement Science Review,2014,14(1):41-47.
[16] 杨辉跃,涂亚庆,张海涛,等.一种基于LMS的振动信号相位差自适应无偏估计方法及应用[J].振动与冲击,2016,35(10):55-59. YANG HY,TU YQ,ZHANG HT,et al.LMS based phase difference adaptive unbiased estimation method and its application[J].Journal of Vibration and Shock,2016,35(10):55-59.(in Chinese)
[17] Kay S.Fundamentalsof Statistical Processing(Volume 1:Estimation Theory)[M].New Jersey:A Simon & Schuster Company,1993.294-295.
[18] 涂亚庆,李明,沈廷鳌,等.计及负频率的DFT与DTFT相位差测量误差分析[J].振动与冲击,2015,34(20):85-91. TU YQ,LI M,SHEN TA,et al.Error analysis of DFT and DTFT based phase difference measurement with negative frequency contribution[J].Journal of Vibration and Shock,2015,34(20):85-91.(in Chinese)
[19] 李叶,徐科军,朱志海,等.面向时变的科里奥利质量流量计信号的处理方法研究与实现[J].仪器仪表学报,2010,31(1):8-14. LI Y,XU KJ,ZHU ZH,et al.Study and implementation of processing method for time-varying signal of coriolis mass flowmeter[J].Chinese Journal of Scientific Instrument,2010,31(1):8-14.(in Chinese) |