康国新, 邹寿彬, 陈良怡, 等. 膜片钳放大器的低噪声设计[J]. 电子学报, 2000,28(9):42-45.
KANG Guo-xin, ZOU Shou-bin, CHEN Liang-yi, et al. Low Noise Design of Patch Clamp Amplifier[J]. Acta Electronica Sinica, 2000, 28(9): 42-45.
本文论述用于测量细胞膜离子通道电流的放大器的电路方案.因被测电流在1pA到nA级的范围内
而输出电压要求达到计算机便于处理的数值.故需采用多级放大电路.被测电流属极微弱的信号
噪声问题是设计中的关键.对于多级放大器来说
前置放大级(探头电路)的低噪声设计至关重要.文中分析放大电路中的主要元、器件的背景噪声
用噪声电流和噪声电压的功率密度谱(PDS)
S
I
(f)和S
v
(f)
来表征其特性.给出了所设计的PC-Ⅱ型膜片钳放大器的主要性能参数和记录的电流波形.
The configuration of the amplifier for recording the ionic channel current of the cell is described here.The measured currents vary from 1 pA to nanoampers
and the output voltage is required to be processed by the computer.Therefore
the amplifier must be constructed in multistages.The key point for designing this amplifier is the low noise technique
especially for the headstage.The background noise of the main components and devices are particularly analyized with power density spectrum
S
I
(f)
and
S
v
(f
) to characterize their characteristics.The test results of the designed patch clamp amplifier model PC-Ⅱ satisfy the practical requirement and the experimental data are given.